Characteristics

Material
galvanised steel
Type
panel
Room/use
for office, for entryways
Location
indoor
Technical characteristics
acoustic, flame-retardant, A2-s1, d0
Aesthetics
perforated
Ecological characteristics
VOC-free, sustainable, recyclable
Width

300 mm
(12 in)

Length

Min.: 900 mm
(35 in)

Max.: 2,420 mm
(95 in)

Thickness

0.6 mm
(0.024 in)

Description

Safety: 30-minute fire resistance (France and Belgium) Safety: hooks to prevent panels from falling if completely opening a ceiling frame Acoustics: high degree of correction, absorption factor αw up to 1 Opening: wide access to the plenum Related system : Self-supporting panel on Omega bandraster system, fire-resistant PM8 SF Hook-On [PLAFOMETAL-SC-130] ACOUSTIC ABSORPTION αw up to 0.80 with the ALPHA range αw up to 1 with the ALPHA PLUS range Check out our video "Acoustic metal ceilings" in our Learning Center. ACOUSTIC FILLING ALPHA offer: black acoustic fleece bonded to the back of perforated ceilings. ALPHA PLUS offer: encapsulated insulating wool to put on the back of perforated ceilings. Acoustic performances of ceilings are guaranteed for products defined, controled and entirely delivered by Plafometal. LIGHT REFLEXION Up to 87%. FIRE REACTION According to EN 13501-1 : Euroclass A1 for the prepainted non-perforated Euroclass A1 for the prepainted in the ALPHA range Euroclass A2-s1, d0 for non-perforated powder post-painted Euroclass A2-s1, d0 for powder post-painted in the ALPHA range Euroclass A2-s1, d0 for the product in the ALPHA PLUS range FIRE RESISTANCE France Pm8 Fire-resistant versions offers fire-resistance performance of FS 1/4 h and FS 1/2 h pursuant to the test described in Appendix 1. £ 2.5 of the Regulation of March 22, 2004, and meet applicable French fire regulations for shared-use corridor inside high-rise buildings.