Compact S is an energy-efficient total indoor climate solution for all types of low-energy buildings, single-family homes, flats and small office areas in commercial leases with a ventilation requirement of up to 375 m3/h.
Compact S recovers the energy from the extracted air using a highly efficient counter flow heat exchanger. The remaining energy that is not utilised by the counter flow heat exchanger is used by the heat pump to produce hot water, and to further heat the supply air.
The heat pump has a reversible cooling circuit, which means that, in the summer, the unit can cool the supply air by up to 10 °C. Due to the low air exchange, the cooling does not function as an air conditioning system. On cooling, the supply air is dehumidified, which gives a more pleasant indoor climate than is possible with an ordinary ventilation unit without a heat pump.
* 1 Input without heating element (accessory).
* 2 Input Compact Polar
* 3 At ± 250 Pa and 265 m3/h according EN 13141-7.
* 4 At ± 100 Pa and 265 m3/h according EN 13141-7.
Capacity
Capacity of standard unit as a function of qv and Pt, ext
SEL values according to EN 13141-7 are for standard units with standard filters ISO Coarse >90% (G4) and without heating element.
SEL values comprise the unit’s total power comsumption incl. control.
Conversion factior: J/m3 : 3600 = W/m3/h
Attention! The SEL values are measured and stated as a total value for both fans.
Temperature efficiency
Temperature efficiency for units with counterflow heat exchanger according to EN13141-7
Sound data
Sounddata is for qv = 210 m3/h and Pt, ext = 100 Pa in accordance with EN 9614-2 for surface and EN 5136 for ducts.