Fire protection façade with fire resistance rating 30 minutes
-Elevation widths 50 mm
-Maximum pane size 1500 mm x 3000 mm
-Fire protection façade EI30
-Fixing spacings ≤ 6000mm
Construction:
Thermally insulated aluminium façade design in mullion-transom construction for vertical façade walls (mounting position tilted by up to 10° from the vertical)
Mullion, transom and cover profiles from the Hueck Trigon modular façade system; slide-in supplementary profile including non-combustible insulating strips. Insulating zone formed by an insulating layer strip and glass fibre-reinforced polypropylene as a spacer profile
Same geometry for mullion and transom
Elevation width: Transom and cover profiles with an elevation width of 50 mm in various profile geometries
Field of application:
The permitted height of fixing points for the glazed storeys is ≤ 6000 mm in the case of mullion profiles
The width and height of the façade construction is unlimited
The max. mullion spacings are ≤ 3024 mm
Glazing:
Contraflam single glazing Securit, Securit Decorglass, Stadip, Stadip Protect Thickness: ≥ 16 mm
Contraflam insulating glazing Climalit, Climaplus, Climatop, ScreenLine Thickness: ≥ 26 mm
Max. permissible glass size for EI30 (F30): 1500 x 3000 mm, in a choice of vertical or horizontal format
Highlights:
Water tightness: Static class RE 750 according to DIN EN 12154, dynamic class 250 / 750 Pa according to DIN EN 13050
Air permeability: Class A4 according to DIN EN 12 152
Resistance to wind load: Test load 2000 Pa / safe load 3000 Pa according to DIN EN 13116
Permissible load: 2.4 kN/m²; increased load: 3.6 kN/m²