Home Control Unit supports the functions of gateway, mix controller, dry contact, and LED output. The Home Control Unit has 22 channel outputs, 24-channel dry contacts and 11-channel LED outputs.
Mix control functions
• 22 zones can be set, and each zone includes 0-12 scenes.
• Channel 1 to 13 are relay outputs, and each channel outputs 5A current. The load types are recommended to be incandescent lamp, halogen lamp, low voltage halogen lamp.
• Channel 14 to 17 are relay outputs, and each channel outputs 10A current. The load types are recommended to be
incandescent lamp, halogen lamp, low voltage halogen lamp.
• Channel 18 to 21 are dimming outputs, each channel outputs 0.8A current. It has short circuit protection with replace D
able fuse. When the fuse is burned, the fuse indicator will flash.
• Channel 22 is 1A relay output channel.
Dry contact
• 24-channel dry contact inputs.
LED output function
• 11-channel switch indicator outputs.
RS485 function
• 1CH external RS485 Bus data receiving and sending, internally converted into HDL Buspro protocol commands.
Internet function
• Local connection control or remote connection configuration.