Standard H blocks have internal insulation and 15 cm of concrete.
Explanatory note
1. Net dry density = (500÷50) Kg/m3
2. Sintered expanded polystyrene with graphite additive. Density = 0.15 KN/m3; A = 0.031 W/m.K
3. Concrete density 25 KN/ m2; dry A = 1.72 W/m.K; ^ = 1.91 W/m.K with humidity in equilibrium with air at 23° C and 50% RH (ref. UNI EN 1745 and UNI EN 12524).
4. R= Dry thermal resistance without coating and without thermal resistance limitation. Evaluation according to the theoretical method UNI EN 1745:2012. Three-dimensional method.
5. U= Dry thermal transmittance, with 2 cm lime-sand render on the outside, 2 cm lime-sand render on the inside, with limit thermal resistance, in dry conditions. Evaluation according to UNI EN 1745:2012 theoretical method. Three- dimensional method.
6. R= Thermal resistance, without plaster, without limitation of thermal resistance and with humidity in equilibrium with air at 23° C and 50% RH. Evaluation according to the theoretical method UNI EN1745:2012. Three-dimensional method.
7. U= Thermal transmittance, with 2 cm lime-sand render on the outside, 2 cm lime-sand render on the inside, with limiting thermal resistance and humidity in equilibrium with the air at 23° C and 50% relative humidity. Assessment according to UNI EN 1745:2012 theoretical method. Three-dimensional method.
8. Ref. UNI - EN ISO 10456 standard for a 24-hour period
9. Certified value of theoretical calculation UNI EN 12354-1:2002
10. Ref. UNI 1365-1 standard. REI :
- Strength: ability to maintain structural stability
- Airtightness: ability to prevent the spread of fire and smoke through the air.