Exterior bottom shall be heavy-gauge galvanized metal.
Exterior ends shall be heavy gauge stainless steel.
Base interior shall be one-piece thermoformed ABS plastic material, with integral shelf supports. ABS interior is backed by a limited lifetime warranty. Base shall be fully insulated with high-density foamed-in-place environmentally friendly, Kyoto Protocol Compliant, Non ODP (Ozone Depletion Potential), Non GWP (Global Warming Potential) polyurethane.
Door shall have a heavy-gauge stainless steel exterior, with a thermoformed ABS plastic interior liner, and shall be fully insulated with foamed-in-place polyurethane. Door handle shall be black, recessed ABS. Cabinet shall have (1) adjustable epoxy-coated wire shelf installed.
Freezers only: Freezer system shall use R290 refrigerant. Compressor shall be 1/5 h.p., with condenser coil, hot gas condensate evaporator and temperature control mounted on rear of cabinet. Evaporator coil shall be mounted on the interior rear wall of the cabinet. Refrigerant flow shall be controlled by a capillary tube. Cabinet shall maintain -5°F to 0°F (-21°C to -18°C) interior cabinet temperature.
Electrical Connections: 115 volt, 60 Hertz, single phase. Unit shall have a 6' (1.8 m) long electrical cord and NEMA 5-15P plug. Cord and plug shall be located on the rear of the cabinet 16" (40.6cm) above floor, 5" from left side.
Electrical connections shall be 230-240 volt, 50 Hertz, single phase. Unit shall have a 6’ (1.8m) long electrical cord and CEE 7/7 plug. Cord and plug shall be located on rear of cabinet, 16” (41 cm) above floor, 5” (13 cm) from left side.