Type Marine three-ways smoke boiler with water production for heating; Boiler shell in steel at 3 bar pressure; Doors for internal inspections and boiler cleaning; Cast iron burner with mechanical feeding system; Cylindrical combustible feeding hopper with mechanical stirrer; Fire fighting system in the hopper; Variable speed screew for automatic feeding; Primary and secondary combustion air system; Voltage: 230 V up to 100 kW, 400 V from 130 kW up to 4100 kW.
Optional
Electronic board for combustible automatic ignition, fire maintenance and modulation for CSA 30-100 mod. boiler
Electronic control board (as specified above) with lambda sensor control device for CSA 30-100 mod. boiler
Electromechanical board for CSA 130-4100 mod. boiler
Electromechanical/electronic combined control board for combustible automatic ignition, fire maintenance, modulation and remote control system for CSA 130-4100 mod. boiler
Electromechanical/electronic combined control board (as specified above) with lambda sensor control device and remote control sytem for CSA 130-4100 mod. boiler
Ashes extractor device (cleaning efficiency 60-70%)
Refractory panels into combustion chamber
Retards for heat holding inside the tubes nest
Automatic combustible feeding system supplied with electric board and (min/max) screw level gauges on the hopper
Kit for sanitary water production, (efficiency output: from 20 to 33 kW; complete with exchanger plates, pump circulation, flow switch and three way valve)
Rotary valve (to prevent flame return into the hopper)
Tube nest pneumatic cleaning system (cleaning efficiency 60-70%). Compressor excluded from 130 kW up.