Tested according to EN 13229 W EN 13229 WA
Values measured at Rated capacity Accumulation
Suitable for all construction types according to rules OK OK
EEI 120.1 120.1
Data for functional demonstration
Fire wood volume kg/h 2.5 4
Combustion performance kW 11 17
Flue gas mass flow g/s 10 17
Outlet temperature (before heating surface) °C 495 520
Flue gas temperature after:
1 x adjoining cast iron radiator (GNF 8/10) °C 122 165
1 x accumulation rings (MAS) 1) °C 220 -
4,1 m ceramic accumulator 2) °C - 180
accumulation stones (MSS) 2) °C - 215
boiler °C 210 -
Necessary supply pressure Pa 12 15
Combustion air consumption m3
/h 25 45
Combustion air connection Ø mm 125 125
Heat distribution
Insert / heat accumulator % 45 / 40 - 45 45 / 40 - 45
Glass pane (single / double) % 15 / 10 15 / 10
Cross-section of gratings 3)
Convection air cm2 500 / 250 / 550 500 / 250 / 550
Supply air cm2 500 / 250 / 550 500 / 250 / 550
Minimal distances of the fireplace
to insulation layer cm 6 6
to mounting floor cm 15 15
Thermal insulation without / with air gratings 4)
Mounting wall cm 12 / 8 12 / 8
Floor cm 0 0
Ceiling cm 22 / 16 22 / 16
Isolation around the additional door 6 6
Brick lining for combustible wall cm 10 10
Weight
Fireplace / combustion chamber kg 63
Meets requirement/limit values for:
Germany/ Austria / Suisse / Norway 1.BImSchV (Stufe 2) / 15a BVG (2015) / LRV / -