Tested according to EN 13229 W EN 13229 WA
Values measured at Rated capacity Accumulation
Suitable for all construction types according to rules OK OK
EEI 114.3 114.3
Data for functional demonstration
Fire wood volume kg/h 2.7 5.5
Combustion performance kW 10.5 22
Flue gas mass flow g/s 8.5 20
Outlet temperature (before heating surface) °C 460 540
Flue gas temperature after:
1 x adjoining cast iron radiator (GNF 8/10) °C 180 215
7 x accumulation rings (MAS) 1) °C 220 -
4,9 m ceramic accumulator 2) °C - 180
3,4 m accumulation stones (MSS) 2) °C - 190
Necessary supply pressure Pa 12 15
Combustion air consumption m3
/h 25 48
Combustion air connection Ø mm 125 / 160 125 / 160
Heat distribution
Insert / heat accumulator % 30 / 40 30 / 40
Glass pane (single / double) % - / 30 - / 30
Cross-section of gratings 3)
Supply air cm2 700 / 300 / 500 700 / 300 / 500
Warm air cm2 700 / 300 / 500 700 / 300 / 500
Minimal distances of the fireplace
to insulation layer cm 8 8
to mounting floor cm 15 15
Thermal insulation without / with air gratings 4)
Mounting wall cm 12 / 10 12 / 10
Floor cm 0 0
Ceiling cm 22 / 16 22 / 16
Brick lining for combustible wall cm 10 10
Weight
Fireplace / combustion chamber kg 307 / 46
Meets requirement/limit values for:
Germany/ Austria / Suisse / Norway 1.BImSchV (Stufe 2) / 15a BVG (2015) / LRV / -